Heat Calculations Equations - Equations for heat-up and operating requirements with additional considerations for heat loss and other factors |
Kilowatt hours to Heat Steel: |
KW= |
Kilograms X Temperature Rise(°C) —————————————— |
5040 X Heat-Up Time (hrs) |
Kilowatt hours to Heat Oil: |
KW= |
LitersX Temperature Rise (°C) —————————————— |
1680 X Heat-Up Time (hrs) |
Kilowatt hours to Heat Water: |
For Heating Water in Tanks: |
KW= |
Liters Temperature Rise (°C) —————————————— |
790 X Heat-Up Time (hrs) |
For Heating Flowing Water: |
KW= |
Liters/min. X Temperature Rise (°C) X 0.076 —————————————— |
Kilowatt hours to Heat Air: |
For Air |
KW= |
Cubic Meters /Min(1) X Temperature Rise (°C) —————————————— |
47 |
For Compressed Air: |
KW= |
Cubic Meters /Min (2) X Temperature Rise (°C)X Density (Kg/m3) (2) —————————————— |
57.5 |
(1) Measured at normal Temperatures & Pressure
(2) Measured Heater System Inlet Temperature and Pressure |